Uploaded image for project: 'Magnolia'
  1. Magnolia
  2. MAGNOLIA-5497

Missing outputstream close in transporter prevents deletion of mgnl_activation temp files - Port to 4.5.x, 4.4.x

    XMLWordPrintable

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: 4.4.13, 4.5.14
    • Component/s: activation
    • Labels:
    • Environment:
      Windows jre6 magnolia 4.5.6
    • Sprint:
      5.2-rc2
    • Magnolia Release:
      4.4.13, 4.5.14

      Description

      Might be not the right project, please move if needed.
      Closing of DataOutputStream dos is missing from info.magnolia.module.exchangesimple.Transporter prepareTempFile method. This suspectedly prevents in most cases the deletion of temporary .mgnl_activation files in Transporter.transport method.
      It seems that this problem can be found in 5.0 sources as well.

        Attachments

          Issue Links

            Activity

              People

              Assignee:
              mdivilek Milan Divilek
              Reporter:
              vpeter Peter Varga
              Votes:
              0 Vote for this issue
              Watchers:
              1 Start watching this issue

                Dates

                Created:
                Updated:
                Resolved: