Uploaded image for project: 'Activation'
  1. Activation
  2. MGNLACTIVATION-25

Missing outputstream close in transporter prevents deletion of mgnl_activation temp files

XMLWordPrintable

    • Icon: Bug Bug
    • Resolution: Fixed
    • Icon: Major Major
    • 5.1.1, 5.2
    • 5.0
    • Windows jre6 magnolia 4.5.6

      Might be not the right project, please move if needed.
      Closing of DataOutputStream dos is missing from info.magnolia.module.exchangesimple.Transporter prepareTempFile method. This suspectedly prevents in most cases the deletion of temporary .mgnl_activation files in Transporter.transport method.
      It seems that this problem can be found in 5.0 sources as well.

        Acceptance criteria

              mdivilek Milan Divilek
              vpeter Peter Varga
              Votes:
              0 Vote for this issue
              Watchers:
              2 Start watching this issue

                Created:
                Updated:
                Resolved:

                  Bug DoR