SilentXASyndicator can't be reinstantiated by N2B

    XMLWordPrintable

Details

    • Bug
    • Resolution: Fixed
    • Neutral
    • 1.6
    • 1.6
    • None
    • None
    • Sprint 5 (Kromeriz)
    • 2

    Description

      Any change in configuration of any command makes the synchronisation command unusable. This is due to N2B instantiation of /modules/synchronization/commands/synchronization/synchronize/syndicator@class. It tries to inject SimpleTranslator but info.magnolia.i18nsystem.TranslationService cannot be injected outside of MgnlContext.
      The latest versions of activation and XAA don't need SimpleTranslator.

      Checklists