[MGNLSYNC-28] SilentXASyndicator can't be reinstantiated by N2B Created: 13/Aug/15  Updated: 29/Mar/22  Resolved: 13/Aug/15

Status: Closed
Project: Magnolia Synchronization Module
Component/s: None
Affects Version/s: 1.6
Fix Version/s: 1.6

Type: Bug Priority: Neutral
Reporter: Roman Kovařík Assignee: Roman Kovařík
Resolution: Fixed Votes: 0
Labels: None
Remaining Estimate: 0d
Time Spent: 1h
Original Estimate: Not Specified

Template:
Acceptance criteria:
Empty
Task DoD:
[ ]* Doc/release notes changes? Comment present?
[ ]* Downstream builds green?
[ ]* Solution information and context easily available?
[ ]* Tests
[ ]* FixVersion filled and not yet released
[ ]  Architecture Decision Record (ADR)
Bug DoR:
[ ]* Steps to reproduce, expected, and actual results filled
[ ]* Affected version filled
Sprint: Sprint 5 (Kromeriz)
Story Points: 2
Team: Nucleus

 Description   

Any change in configuration of any command makes the synchronisation command unusable. This is due to N2B instantiation of /modules/synchronization/commands/synchronization/synchronize/syndicator@class. It tries to inject SimpleTranslator but info.magnolia.i18nsystem.TranslationService cannot be injected outside of MgnlContext.